Typical applications:
Type | IF160 | IF250 | IF400 | IF600 | IF800 | IF1000 | IF1300 | IF2000 |
---|---|---|---|---|---|---|---|---|
Capacity when heating steel up to 1250oC | 400kg/h | 650kg/h | 1000kg/h | 1500kg/h | 2000kg/h | 2500kg/h | 3000kg/h | 4500kg/h |
Active power | 160kW | 250kW | 400kW | 600kW | 800kW | 1000kW | 1300kW | 2000kW |
Typical frequency | 4÷20 kHz | 3÷10 kHz | 2÷8 kHz | 1÷3 kHz | 0,5÷2 kHz | 0,5÷2 kHz | 0,5÷2 kHz | 0,5÷1 kHz |
Typical billets diameter or square | Ø10÷Ø30mm | Ø15÷Ø50mm | Ø20÷Ø70mm | Ø30÷Ø90mm | Ø40÷Ø110mm | Ø50÷Ø130mm | Ø60÷Ø160mm | Ø80÷Ø240mm |
Typical billets transport level | 1400mm | 1400mm | 1600mm | 1600mm | 1600mm | 1600mm | 1800mm | 2000mm |
Max. heating temp. | 1300 st C | 1300 st C | 1300 st C | 1300 st C | 1300 st C | 1300 st C | 1300 st C | 1300 st C |